Modular Device Versatility
The smartblock series excels with its wide range between 7.5 to 75 kWel, but also because of the modular features by means of which all devices can be comined and controlled centrally and jointly.
Our smartblocks for insular mode
smartblock 16s
The calculation of the required power rating of the CHP is based primarily on the heating requirements of the object (house, residential block, company building). The smartblock 16s is best suited if the energy requirements are in the range of approx. 220,000 to 600,000 kWh/a. As a rule of thumb think of an annual gas consumption of approx. 22,000 to 60,000 m³.
Type | smartblock 16s | |
Operational Mode | Insular Mode | |
Fuel | Natural Gas (NG) | Liquid Petrol Gas (LPG) |
Performance Details | - NG - | - LPG - |
Electric Output | 16.0 kW | 16.0 kW |
Modulation Range | 50 - 100% | 50 - 100% |
Thermal Output | 34.5 kW | 36.7 kW |
Fuel Consumption* | 51.6 kW | 55.4 kW |
Electric Efficiency | 31.00% | 28.9 % |
Total Efficiency* | 97.90% | 95.1 % |
Season Efficency **** | 202% | 170.7 % |
Energy Efficiency** | A++ | A+ |
Exhaust Gas Emissions | ||
CO (carbon monoxide) | < 100 mg/m³ | |
NOx (nitrogen oxide) | < 100 mg/m³ | |
Sound Pressure Level*** | 50.1 dB(A) | 53.2 dB(A) |
Dimensions | ||
L / W / H CHPP | 1.47/ 0.82 / 0.98 m | 1.47/ 0.82 / 0.98 m |
Weight CHPP | 670 kg | 740 kg |
Download Datasheets | ||
→ Datasheet sb 16s NG | → ErP Datasheet sb 16s NG | → Datasheet sb 16s LPG |
→ Dimensions CHP | → Dimensions Control Cabinet | |
→ Connections CHP | → Connections Control Cabinet | |
→ Electric Connections CHP | ||
* EN50465 Tolerance +5% ** RL 2010/30/EU, VOs 811+813/2013 *** DIN EN ISO 3744 1m Distance **** Season efficency according EN50465 |
smartblock 22s
The calculation of the required power rating of the CHP is based primarily on the heating requirements of the object (house, residential block, company building). The smartblock 22s is best suited if the energy requirements are in the range of approx. 290,000 to 720,000 kWh/a. As a rule of thumb think of an annual gas consumption of approx. 29,000 to 72,000 m³.
Type | smartblock 22s | |
Operational Mode | Insular Mode | |
Fuel | Natural Gas (NG) | Liquid Petrol Gas (LPG) |
Performance Details | - NG - | - LPG - |
Electric Output | 22.0 kW | 22.0 kW |
Modulation Range | 50 - 100% | 50 - 100% |
Thermal Output | 49.6 kW | 51.4 kW |
Fuel Consumption* | 68.6 kW | 72.7 kW |
Electric Efficiency | 32.10% | 30.20% |
Total Efficiency* | 104.40% | 100.90% |
Season Efficency **** | 198% | 200% |
Energy Efficiency** | A++ | A++ |
Exhaust Gas Emissions | ||
CO (carbon monoxide) | < 100 mg/m³ | |
NOx (nitrogen oxide) | < 100 mg/m³ | |
Sound Pressure Level*** | 50.6 dB(A) | |
Dimensions | ||
L / W / H CHPP | 1.61/ 0.82 / 0.98 m | |
Weight CHPP | 770 kg | |
Download Datasheets | ||
→ Datasheet sb 22s NG | → Datasheet sb 22s LPG | |
→ ErP Datasheet sb 22s NG | → Datasheet sb 22s LPG ErPLabel | |
→ Dimensions CHP | → Dimensions Control Cabinet | |
→ Connections CHP | → Connections Control Cabinet | |
→ Electric Connections CHP | ||
* EN50465 Tolerance +5% ** RL 2010/30/EU, VOs 811+813/2013 *** DIN EN ISO 3744 1m Distance **** Season efficency according EN50465 |
smartblock 33s
The calculation of the required power rating of the CHP is based primarily on the heating requirements of the object (house, residential block, company building). The smartblock 33s is best suited if the energy requirements are in the range of approx. 380,000 to 850,000 kWh/a. As a rule of thumb think of an annual gas consumption of approx. 38,000 to 85,000 m³.
Type | smartblock 33s | |
Operational Mode | Insular Mode | |
Fuel | Natural Gas (NG) | Liquid Petrol Gas (LPG) |
Performance Details | - NG - | - LPG - |
Electric Output | 33.0 kW | 33.0 kW |
Modulation Range | 50 - 100% | 50 - 100% |
Thermal Output | 68.1 kW | 71.1 kW |
Fuel Consumption* | 97.0 kW | 103.6 kW |
Electric Efficiency | 34.00% | 31.90% |
Total Efficiency* | 104.20% | 100.50% |
Season Efficency **** | 273% | 220% |
Energy Efficiency** | A++ | A++ |
Exhaust Gas Emissions | ||
CO (carbon monoxide) | < 100 mg/m³ | |
NOx (nitrogen oxide) | < 100 mg/m³ | |
Sound Pressure Level*** | 54.3 dB(A) | |
Dimensions | ||
L / W / H CHPP | 1.79 / 0.91 / 1.11 m | |
Weight CHPP | 1060 kg | |
Download Datasheets | ||
→ Datasheet sb 33s NG | → ErP Datasheet sb 33s NG | → Datasheet sb 33s LPG ErPLabel |
→ Dimensions CHP | → Dimensions Control Cabinet | |
→ Connections CHP | → Connections Control Cabinet | |
→ Electric Connections CHP | ||
* EN50465 Tolerance +5% ** RL 2010/30/EU, VOs 811+813/2013 *** DIN EN ISO 3744 1m Distance **** Season efficency according EN50465 |
smartblock 50s
The calculation of the required power rating of the CHP is based primarily on the heating requirements of the object (house, residential block, company building). The smartblock 16 is best suited if the energy requirements are in the range of approx. 560,000 to 1,050,000 kWh/a. As a rule of thumb think of an annual gas consumption of approx. 56,000 to 105,000 m³.
Type | smartblock 50s |
Operational Mode | Insular Mode |
Fuel | Natural Gas (NG) |
Performance Details | - NG - |
Electric Output | 50.0 kW |
Modulation Range | 50 - 100 % |
Thermal Output | 100.2 kW |
Fuel Consumption* | 142.7 kW |
Electric Efficiency | 35.00% |
Total Efficiency* | 35.00% |
Energy Efficiency** | 105.20% |
Season Efficency **** | 269% |
Exhaust Gas Emissions | A++ |
CO (carbon monoxide) | |
NOx (nitrogen oxide) | < 100 mg/m³ |
Sound Pressure Level*** | < 100 mg/m³ |
Dimensions | 56.6 dB(A) |
L / W / H CHPP | |
Weight CHPP | 2.29 / 0.96 / 1.71 m |
Operational Mode | 2020 kg |
Download Datasheets | |
→ Datasheet sb 50s K49S NG | → ErP Datasheet sb 50s NG |
→ Datasheet sb 50Ts 50Hz | → Datasheet sb 50Ts 60Hz |
→ Dimensions CHP | → Dimensions Control Cabinet |
→ Connections CHP | → Electric Connections CHP |
* EN50465 Tolerance +5% ** RL 2010/30/EU, VOs 811+813/2013 *** DIN EN ISO 3744 1m Distance **** Season efficency according EN50465 |
Type | smartblock 75s |
Operational Mode | Insular Mode |
Fuel | Natural Gas (NG) |
Performance Details | - NG - |
Electric Output | 75.0 kW |
Modulation Range | 50 - 100 % |
Thermal Output | 139.8 kW |
Fuel Consumption* | 209.6 kW |
Electric Efficiency | 35.80% |
Total Efficiency* | 102.50% |
Season Efficency **** | 302% |
Energy Efficiency** | A++ |
Exhaust Gas Emissions | |
CO (carbon monoxide) | < 100 mg/m³ |
NOx (nitrogen oxide) | < 100 mg/m³ |
Sound Pressure Level*** | 56.8 dB(A) |
Dimensions | |
L / W / H CHPP | 2.64 / 0.96 / 1.71 m |
Weight CHPP | 2600 kg |
Download Datasheets | |
→ Datasheet sb 75s NG | → ErP Datasheet sb 75s NG |
→ Dimensions CHP | → Dimensions Control Cabinet |
→ Connections CHP | → Electric Connections CHP |
* EN50465 Tolerance +5% ** RL 2010/30/EU, VOs 811+813/2013 *** DIN EN ISO 3744 1m Distance **** Season efficency according EN50465 |